3Com 10014299 Network Router User Manual


 
CE3 Interface 147
Table 164 Enter the view of the specified E3 interface
2 Set Clock Mode of CE3 Interface
Perform the following configuration in CE3 interface view.
Table 165 Set clock mode of the CE3 interface
By default, CE3 interface uses slave clock.
The user can also set clock mode for E1 channels of CE3 interface.
Table 166 Set clock mode of the E1 channel
By default, E1 channel uses slave clock.
3 Set National Bit for CE3 Interface
Perform the following configuration in CE3 interface view.
Table 167 Set a national bit of the CE3 interface
By default, national bit of CE3 interface is 1.
4 Set the Loopback Mode of CE3 Interface
Perform the following configuration in CE3 interface view.
Table 168 Set loopback mode of CE3 interface
By default, loopback is disabled.
Single-channel loopback can be set on the E1 channels on a CE3 interface, and
the settings of individual channels are independent.
Table 169 Set loopback mode of E1 channel
5 Set E1 Frame Format
Operation Command
Enter the view of CE3 interface controller e3 number
Operation Command
Set clock mode of the CE3 interface clock { master | slave }
Restore the default clock mode of CE3 interface undo clock
Operation Command
Set clock mode of the E1 channel e1 line-number set clock {
master | slave }
Restore the default clock mode of E1 channel undo e1 line-number set
clock
Operation Command
Set national bit of the CE3 interface national-bit { 0 | 1 }
Restore the default national bit undo national-bit
Operation Command
Set loopback mode of CE3 interface loopback { local | payload |
remote }
Disable loopback on the CE3 interface undo loopback
Operation Command
Set loopback mode of E1 channel e1 line-number set loopback
{ local | remote }
Disable loopback on the E1 channel undo e1 line-number set
loopback