6-38 August 2003 Access Navigator - Release 1.8
Electrical Installation
Dress Cables and Wires
Dress Cables and Wires
Installation Summary
n Tools and Materials ... 6-38
n Dress Cables and Wires ... 6-38
Tools and Materials
Obtain the following tools and materials:
• Pliers, needle nose
• Cutters, diagonal
• Wire ties (3 ea.), part of Accessory Kit, PN 003-0247
Dress Cables and Wires
Dress cables and wires as follows.
• Follow standard practice.
• If desired, use wire tie anchors on rear panel (see Figure 6-25) to secure wires.
• Ferrite bead RF suppressors may be moved slightly to allow for securing wire ties.
• When mounted horizontally, the ground wire and DSX-1 cables are normally dressed toward
left side of rack and all other cables and wires are dressed toward right side, as viewed from
connector panel (Figure 6-25).
• Ensure that no bare wires are exposed after dressing.
Figure 6-25. Location of Rear Panel Wire Tie Anchors and Connectors
Wire Tie Anchor
Wire Tie Anchor
DSX-1 Cable
DSX-1 Cable
Ground Timing Alarm -48V Alarm -48V Ethernet RS-232
ACLIBOutIn In
Wire