Carrier Access Access Navigator Network Router User Manual


 
Access Navigator - Release 1.8 August 2003 10-9
Provision GR-303 Service
GR-303 Provisioning Quick Guide
GR-303 Provisioning Quick Guide
CLI Commands Descriptions
status equipment Verify equipment configuration.
show ds1 <n|all>
status ds1 <n>
status ds0 <n:ch>
Verify service status.
set ds1 <n> down
set ds0 <n:ch> down
set ds0 <n:ch> type <voice|data>
Set unused circuits out of service
(down). If the DS1 is not terminated,
set the DS0 type of all channels to
data. If the DS1 is terminated, set the
DS0 type of any unused channels to
match the DS0 type (voice or data)
configured on the device at the other
end of the DS1.
set clock1 <bits|ds1 n|internal> Primary system clock source.
set clock2 <bits|ds1 n|internal> Secondary system clock source.
set switch type <5ess|dms|generic> Ensures switch compatibility.
set ds1 <n> type <switch|groom|drop> DS1 type.
set ds1 <n> framing <d4|esf|slc96> DS1 framing.
set ds1 <n> linecode <ami|b8zs> DS1 line code.
set ds1 <n> id <"id"> DS1 identifier.
set ds1 <n> termid <id> Switch DS1 terminal identifier.
set ds1 <n> clock <normal|loop> DS1 clock source.
set ds1 <n> lbo <setting> DS1 line buildout.
set ds1 <n> fdl <none|slc96|t1403> DS1 FDL type.
set ds1 <n> remote device mgmt
<none|cafdl|caip <ipaddress>|ds1 n>
Management link for remote
Access Bank II and Adit 600.
set ds1 <n> remote device mgmt
caip <ipaddress> pphone
Enables call communications channel
for remote Adit 600 providing
P-Phone service.
set eoc primary <n:ch|none>
set eoc secondary <n:ch|none>
EOC channels.
set tmc primary <n:ch|none>
set tmc secondary <n:ch|none>
TMC channels.
set ds1 <n> loopdetect <on|off> Usually off for drop DS1s.
set ds0 <n:ch> type <voice|data|gr303> DS0 type.
set ds0 <n:ch> pphone P-Phone channels.