Carrier Access Access Navigator Network Router User Manual


 
14-12 August 2003 Access Navigator - Release 1.8
Alarm Clearing
Clear Alarms – EOC
Remote Device #n:
T1 #x rx Yellow alarm
Remote device on DS1 #n
received Yellow alarm (RAI) on
T1 #x. Minor alarm for active
crossconnects.
Clear trouble at remote device.
Remote Device #n: V.35
loss of RTS
Remote device on DS1 #n
reported loss of RTS on V.35
interface. Minor alarm for active
crossconnects.
Clear trouble at remote device.
TMC Primary/
Secondary Link Down
Event Report Service Problem.
TMC LAPD data link
communication not established
with the switch. Access Navigator
periodically retries to establish
LAPD data link with the switch.
Ensure DS1 assigned to TMC is
healthy.
Check status of DS1 assigned for
TMC with the following CLI
command:
status tmc
Check TMC provisioning with the
following CLI command:
show tmc
Use following CLI command to
change setting:
set tmc <primary/secondary> ds1
<n>
System Alarm State
Change
Event Report Service Problem
(5ESS only). The severity of the
system alarm state has changed.
Only those events reportable to the
switch and excluding Service
Problems are included in the
system alarm state.
The alarm is cleared after all
events reportable to the switch
have been cleared.
Table 14-6 EOC Minor Alarm Message and Trouble Clearing Procedure
Event Message Description Trouble Clearing Procedure