Carrier Access Access Navigator Network Router User Manual


 
15-16 August 2003 Access Navigator - Release 1.8
Diagnostics & Troubleshooting
Status DS1 Performance
Status DS1 Performance
Displays current performance data for the specified DS1. The Access Navigator accumulates DS1
performance data for the parameters described in RFC 1406 – Definitions of Managed Objects for the
DS1 and E1 Interface Types. All performance parameters are accumulated in fifteen minute intervals.
The “current” 15 minute interval shows data collected when the command is received, and always
represents an elapsed time of less than 15 minutes. At the end of each 15 minute interval, the Access
Navigator displays the total as the “previous” 15 minute interval and computes new totals for 1 hour and
1 day by summing previous intervals.
The clear ds1 performance command can be used to reset the performance data for a specific
DS1. When this is done, the timer for that DS1 will start at zero hours, minutes, and seconds. (See Clear
DS1 Performance on page 15-18.)
The status performance message will include an asterisk (*) to mark error counts that exceed
the threshold values set by the Set DS1 Threshold on page 18-115. Exceeding a threshold can cause an
automatic alarm message to be sent to the network operations center.
Syntax: status ds1 <n> performance
Example: status ds1 9 performance
Message:
Performance Statistics for DS1 #9
current previous
15 min. 15 min. hour day
-------- -------- -------- --------
unavailable seconds: 0 0 0 0
errored seconds: 1 0 577* 29377*
severely errored seconds: 0 0 0 0
sev. errored frame seconds: 0 0 0 0
Remote Device
Management
n/a – not applicable
CA FDL – Used to provision remote Access Bank II or
establish pass-through management session to Adit 600.
CA IP – Used for IP DS0 management of
remote Adit 600.
CA DS1 <n> – Used for IP DS0 management of remote
Adit 600.
In Service – Management link is in service (up)
Out of Service – Management link is out of service (down).
(See Set DS1 Remote Device Mgmt on
page 18-113.)
Clock Source Indicates Primary or Secondary if DS1 line receiver is used for
master clock source
Field Description
n DS1 number, 1 to 32, or a range of numbers such as 2-8.
Item Description