Carrier Access Access Navigator Network Router User Manual


 
Access Navigator - Release 1.8 August 2003 11-19
Provision Remote Access Bank II
Provision DS0 Crossconnects
Provision DS0 Crossconnects
1. Show current crossconnect settings with the following command:
show connect <n>
Example: show connect 11
The show command will display the current settings for the specified DS1. For example, the
message for DS1 number 11 would look similar to the following:
Connections for DS1 #11 (CA DS1# 11):
From To Type Interface [--> Port]
---- ----- ----- --------------------
11:01 ..... GR303
11:02 ..... GR303
11:03 ..... GR303
11:04 ..... GR303
11:05 ..... GR303
11:06 ..... GR303
11:07 ..... GR303
11:08 ..... GR303
11:09 ..... GR303
11:10 ..... GR303
11:11 ..... GR303
11:12 ..... GR303
11:13 .....
11:14 .....
11:15 .....
11:16 .....
11:17 09:12 DATA AcmeInternet --> V.35
11:18 09:13 DATA AcmeInternet --> V.35
11:19 09:14 DATA AcmeInternet --> V.35
11:20 09:15 DATA AcmeInternet --> V.35
11:21 09:16 DATA AcmeInternet --> V.35
11:22 09:17 DATA AcmeInternet --> V.35
11:23 09:18 DATA AcmeInternet --> V.35
11:24 09:19 DATA AcmeInternet --> V.35
2. If DS0 crossconnect settings are correct, skip remaining steps.
NOTE: To change existing DS0 connections, you must first disconnect them before
making new connections.
3. Disconnect existing DS0s with the following command:
disconnect <n:ch>
Example: disconnect 25:1-24