Carrier Access Access Navigator Network Router User Manual


 
18-80 August 2003 Access Navigator - Release 1.8
CLI Language Reference
CLI Command List
Example: send ds1 9 payload f1in8 test
For the 1-in-8 and all-zeros patterns, the CLI will provide a progress message
indicating the success (ok) or failure of the command, followed by a pattern detection
message for each second of the test.
Message: Waiting for pattern sync........ok.
Testing line...
08:18:23 Pattern Not Present
08:18:24 Pattern Present
08:18:25 Pattern Present
08:18:26 Pattern Present
08:18:27 Pattern Present
08:18:28 Pattern Present
08:18:29 Pattern Present
08:18:30 Pattern Present
08:18:31 Pattern Present
08:18:32 Pattern Present
Signaling done.
Description:
Item Description
Time Time is recorded in one-second intervals. Format is 24-hour
clock in hours:minutes:seconds with colons to separate the digits,
as in 08:30:45 and 15:22:10.
FBE Number of Frame Bit Errors (4095 maximum) in one-second
interval
BE Number of Bit Errors (4095 maximum) in one-second interval
CRC Number of Cyclical Redundancy Check errors (1023 maximum)
in one-second interval
BPV/LCV Number of Bi-Polar Violations and Line Code Violations
(16,383 maximum) in one-second interval
Totals Total number of errors for 10-second test interval
Error Rates Total error rates measured during the 10-second test interval,
expressed in scientific notation where "e" indicates a power of
10. For example, 1 error per 1.544 megabits is 6.520000e-07.