Access Navigator - Release 1.8 August 2003 18-121
CLI Language Reference
CLI Command List
Syntax: set remote <n> rs232 baud <setting>
Example: set remote 9 rs232 baud 57600
Set Remote RS232 Data
Purpose: Sets Access Bank II remote RS-232 interface data bits and parity.
Security: Level 2 (operator)
Syntax: set remote <n> rs232 data <e7|o7|n8>
Example: set remote 9 rs232 data n8
Set Remote RS232 Stop
Purpose: Sets Access Bank II remote RS-232 interface stop bits.
Security: Level 2 (operator)
Syntax: set remote <n> rs232 stop <1|2>
Example: set remote 9 rs232 stop 1
Field Description
n DS1 number, 1 to 32
setting Baud rate selections are:
1200, 2400, 4800, 9600, 19200, 38400, 57600
Field Description
n DS1 number, 1 to 32
e7 7 bit data, even parity
o7 7 bit data, odd parity
n8 8 bit data, no parity
Field Description
n DS1 number, 1 to 32.
1|2 Number of stop bits, 1 or 2.