Provision Remote Access Bank II
Provision Drop DS1 to Remote Access Bank II
6. Set DS1 remote device management type to Carrier Access FDL with the following command:
set ds1 <n> remote device management cafdl
7. Set drop DS1 clock source to normal or loop with the following command:
set ds1 <n> clock <normal|loop>
Example: set ds1 25 clock normal
8. Set drop DS1 line buildout (lbo) to required DSX-1 equalization or CSU attenuation with the
following command:
set ds1 <n> lbo <setting>
Example: set ds1 25 lbo 8
The setting is a number from 1 to 9, and is defined as follows:
Setting
Definition
1 Set DSX-1 equalization for 0-133 ft.
2 Set DSX-1 equalization for 133-266 ft.
3 Set DSX-1 equalization for 266-399 ft.
4 Set DSX-1 equalization for 399-533 ft.
5 Set DSX-1 equalization for 533-666 ft.
6 Set CSU attenuation for LBO of 0dB.
7 Set CSU attenuation for LBO of -7.5dB.
8 Set CSU attenuation for LBO of -15dB.
9 Set CSU attenuation for LBO of -22.5dB.
NOTE: When loop code detection is turned on, the Access Navigator will respond to
T1.403 ESF bit patterned loop requests. Loop detection is normally turned off for DS1
drops.
9. Set drop DS1 loop request code detection to on or off with the following command:
set ds1 <n> loopdetect <on|off>
Example: set ds1 25 loopdetect on
10. Set drop DS1 circuit ID with the following command:
set ds1 <n> id <"id">
Example: set ds1 25 id "DS1#25"
The ID may contain up to 30 characters and must be enclosed in quote marks.
11. Set remote terminal identification with the following command:
set remote <n> id <"name">
Example: set remote 10 id "Acme Corp"