Carrier Access Access Navigator Network Router User Manual


 
Access Navigator - Release 1.8 August 2003 18-135
CLI Language Reference
CLI Command List
Show Autoexit
Purpose: Displays the current setting for the autoexit timeout.
Security: Level 3 (monitor)
Syntax: show autoexit
Message:
CLI session timeout = 15 minutes.
Show Clock
Purpose: Displays the current settings for the primary and secondary master transmit clock
source.
Security: Level 3 (monitor)
Syntax: show clock
Message:
Primary Master Transmit Clock Source: DS1 12
Secondary Master Transmit Clock Source: INTERNAL
Description:
Show Connect
Purpose: Displays static DS0 connections in the specified DS1. This display will list the current
static DS0 crossconnect settings and dynamic GR-303 voice and ISDN BRI
connections. If a DS0 is part of a fractional interface, the interface name will be shown.
For GR-303 service, the switch assigns GR-303 voice connections as needed, between
switch DS1s and drop DS1s. ISDN BRI using 4:1 TDM mode transport has the D
signaling channel statically connected to a switch DS0, while the switch only sets up
B1 and B2 bearer DS0s as needed between switch DS1s and drop DS1s.
NOTE: ISDN BRI connections using the GR-303 4:1 TDM transport mode
will appear as type GR-303.
Item Description
Clock Source Clock source can be a DS1 line receiver, internal Stratum clock
oscillator, or external Building Integrated Timing Supply
(BITS).