Example of Dictionary Entries in Operator’s Reference
Quality of Service
Specifies the link-level control. It always must remain set to LLC1, the default, for
802.3, 802.5, and PPP circuits.
Default: LLC1
LLC1
Datagram service; best-effort delivery.
LLC2
Reliable service, provides link-level control that includes error detection and error
recovery by retransmission. Results in these additional parameters:
Retry Counter Retry Timer
Connect Retries Link Idle Timer
Modulus Window Size
Remote Address
Accepts a unique decimal value from 00 to 99. Be sure to reverse local and remote
address values when you configure the device at the other end of the PPP circuit.
Default: 07
Range: 00 to 99
Parameter Name
Options for the
Quality of Service
Parameter
Default Setting for Quality of Service
Selecting the LLC2 option for Quality
of Service causes these six other
parameters to appear. Their
descriptions are listed
alphabetically in this chapter.
Operator’s Reference