HP (Hewlett-Packard) 200 Network Router User Manual


 
Net sequence num receive recovery
Meaning: The network is now properly sending keep-alive sequence numbers for
the identified circuit.
Next hop IP
X.X.X.X
has no ph #
Meaning: All map items must have at least one configured phone number. The
map record with with IP next-hop address X.X.X.X has no configured
phone #.
Action: Add a phone number to the IP to V.25 bis mapping record.
New DLCI
XXX
added over existing one
Meaning: For the indicated frame relay circuit, a PVC was marked as new in the
PVC status message before it was removed using the management
interface. The old PVC is deleted and this new one is put in its place.
No buffers to reconnect to remote
Meaning: The circuit indicated in the object field of the event message cannot
establish a connection because of insufficient buffer space.
No Pool circuits config for
X.X.X.X
Meaning: A IP-mapped circuit was configured, but no pool circuits were
configured for the circuit group associated with this static route.
X.X.X.X is the IP address of the associated static route. This
configuration error prevents the V.25 bis to IP map from working. The IP
map is left disabled and the associated IP address will not be reachable
using this map. A result is that all IP addresses accessed by this map will
not be accessible. Attempting to enable the map with the NCL Enipmap
command results in the NCL error message ‘‘Disabled, no pool ccts cfg
for X.X.X.X. (X.X.X.X is the ip address of the next hop associated with
the map.)
Action: Configure the circuit group with V.25 bis pool circuits.
Event Log Messages
cct: Circuit Event Messages
17-38