No buffers available for deadlock processing
Meaning: Indicates a degenerative line condition resulting in the lack of receive
buffers at both the line source and termination.
No circuits configured
Meaning: No circuits are configured.
Action: Modify the configuration to include required circuit records.
No configuration summary record
Meaning: A circuit record is missing from the configuration.
Action: Modify the configuration to ensure that all lines and circuits are defined.
No Ethernet circuits configured
Meaning: HP series 200 and 400 Routers: No Ethernet circuits are config-
ured in the router.
HP J2435A Four-Port Ethernet Interface Module: No Ethernet
circuits are configured in the module.
Action: Modify the line and circuit configuration to include required circuit
records.
No lines configured
Meaning: No lines are configured for the circuits on the router or on the indicated
slot.
Action: Configure one or more lines for the router or indicated slot.
No Token Ring circuits
Meaning: One or more circuits designated by the Circuit Name parameter in the
line record has not been configured.
Event Log
Messages
17
Event Log Messages
dev: Device Event Messages
17-65