Server’s login attempt failed
Meaning: For the indicated PPP circuit, the system failed in its attempt to login to
the remote station. The system User ID or the System Password (or
both) were incorrect.
Action: Modify system User ID and/or System Password in the configuration.
SQE absent (non 802.3 XCVR)
Meaning: The circuit named in the object field of the event message has detected
a loss of the Signal Quality Error (SQE) signal.
Action: Check transceiver hardware. SQE is not supported by Ethernet version
1.0 transceivers.
SR internal LAN ID not in RIF route
Meaning: A specifically routed frame that did not include the internal LAN ID
configured for bridging was received. The packet is dropped.
Action: For information on the Internal LAN ID parameter, refer to chapter 6 in
this manual.
SR is_srf_rif_insert: no rif entry
Meaning: A specifically routed frame was received, but the appropriate entry in
the source-routing intermediate-station table (sr_is_table) does not
contain a routing information field for the destination station. The
packet is dropped.
SR max hops exceeded in explorer frame
Meaning: The maximum number of hops for a source-routed packet, seven, was
exceeded in an all-routes-explorer (ARE) frame or a spanning-tree-
explorer (STE) frame. The packet is dropped.