HP (Hewlett-Packard) 200 Network Router User Manual


 
exmib.fr.dlctble.entry.errthr.cct #
36.26.1.1.7.cct #
where cct # indicates the circuit.
index Is the index into the Dlcmi table. It corresponds to the frame
relay circuit for which table information is requested.
exmib.fr.dlctble.entry.index.cct #
36.26.1.1.1.cct #
where cct # indicates the circuit.
enqlnt Is the number of status enquiry intervals that pass before
issuance of a full status enquiry message. The default is six intervals.
exmib.fr.dlctble.entry.enqlnt.cct #
36.26.1.1.6.cct #
where cct # indicates the circuit.
maxpvc Indicates the maximum number of permanent virtual circuits
(PVCs) allowed for this interface. This is usually dictated by the frame
relay network.
exmib.fr.dlctble.entry.maxpvc.cct #
36.26.1.1.9.cct #
where cct # indicates the circuit.
monevnt Is the number of events for which errors are collected in
order to monitor for an interface shutdown due to excissive error. The
default is four events.
exmib.fr.dlctble.entry.monevnt.cct #
36.26.1.1.8.cct #
where cct # indicates the circuit.
multcast Indicates whether the frame relay provider offers a
multicast service. There are two possible values for this field:
nonBroadcast (1) for those networks that do not support multicasting,
and broadcast (2) for those that do.
Management Information Base Variables
cct: Circuits Information Base
18-26