ccttype[cct#] contains the circuit type defined in the V.25 bis
circuit group definition,either Circuit Group Member, Backup
Member, Pool Member, or Misconfigured Circuit.
connecttime[cct#] contains the value indicating the time in
seconds that the current V.25 bis connection has been alive. If there is no
current connection, then this value indicates the total time that the last
connection was up. If a connection has never been established, the value
is 0.
index[cct#] contains the circuit number for this V.25 bis circuit.
This variable is used with the index number for the first circuit, to find
all the circuit numbers for use in the other variables.
lasterror[cct#] contains the last two ASCII character errors issued
by the terminal adapter. If no error has been set, then it contains None.
lastlog[cct#] contains the last V.25 bis event message for this
circuit.
phonenum[cct#] contains the last phone number called on
outbound connections and the last phone number received on inbound
connections. (On manual connections, this value is set to Unknown. On
inbound connections where the receive number is not passed, it is also
set to Unknown. If no connection has been established since the router
was booted, the value is set to Never used.
state[cct#] indicates the state of this V.25 bis circuit, one of the
following:
Current outbound means the connection was opened in the
outbound direction and is currently open.
Current inbound means the connection was opened in the inbound
direction and is currently open.
Previous outbound means the last connection was opened in the
outbound direction and is currently closed.
Previous inbound means the last connection was opened in the
inbound direction and is currently closed.
Never used means no V.25 bis connection has been established since
the last time the router was booted.
Managment
Information Base
18
Management Information Base Variables
isdn: ISDN (V.25 bis) Information Base