Too many Ethernet circuits configured
Meaning: The configuration contains more Ethernet circuit records than can be
accommodated.
Action: Modify the configuration to ensure that no more than the maximum
Ethernet/802.3 circuit records are assigned.
Too many lines assigned to Ethernet connector
Meaning: The same Ethernet/802.3 line has been assigned to multiple physical
connectors.
Action: Modify the configuration so that only a single line is assigned to each
connector.
Too many lines assigned to V.35 connector
Meaning: The configuration contains an excessive number (greater than two) of
line records for a single connector.
Action: Modify the line configuration to ensure that no more than one line
record references a specific physical connector.
Too many Token Ring circuits configured
Meaning: There can be no more than one token ring circuit configured for each
port on the router. More than one circuit has been configured for a
token ring port.
Action: Reconfigure the token ring circuit(s) to no more than one per port.
Too many Token Ring circuits configured for slot
Meaning: There can be no more than four token ring circuits configured for an HP
Router 650 four-port token ring interface module. More than four
circuits have been configured.
Action: Reconfigure the token ring circuits to no more than one per port.
Event Log
Messages
17
Event Log Messages
dev: Device Event Messages
17-67