HP (Hewlett-Packard) HP 8753E Network Cables User Manual


 
Contents
1.
HP 8753E Description and Options
Where to Look for More Information
.....................
Analyzer Description
.............................
Front Panel Features
.............................
Analyzer Display
..............................
Rear Panel Features and Connectors
.....................
Analyzer Options Available
..........................
Option lD5, High Stability Frequency Reference
...............
Option 002, Harmonic Mode
........................
Option
006,6
GHz
Operation
........................
Option 010, Time Domain
.........................
Option 011, Receiver Configuration
.....................
Option 075,750 Impedance
.........................
Option
lDT,
Delete Display
.........................
Option
lCM,
Rack Mount Flange Kit Without Handles
............
Option
lCP,
Rack Mount Flange Kit With Handles
..............
Service and Support Options
.........................
Differences among the HP 8753 Network Analyzers
..............
2.
B¶akiug
Measurements
Where to Look for More Information
.....................
Principles of Microwave Connector Care
...................
Basic Measurement Sequence and Example
..................
Basic Measurement Sequence
........................
Basic Measurement Example
........................
Step 1. Connect the device under test and any required test equipment.
..
Step 2. Choose the measurement parameters.
...............
Setting the Frequency Range
......................
Setting the Source Power.
.......................
Setting the Measurement
........................
Step 3. Perform and apply the appropriate error-correction.
........
Step 4. Measure the device under test.
..................
Step 5. Output the measurement results.
.................
Using the Display Functions
.........................
‘Ib
View Both Primary Measurement Channels
................
‘Ib
Save a Data Trace to the Display Memory
................
lb View the Measurement Data and Memory Trace
.............
lb
Divide Measurement Data by the Memory Trace
.............
lb Subtract the Memory Trace from the Measurement Data Trace
.......
‘IbRatioMeasurementsinChannelland2
.................
‘Ib
Title
the Active Channel Display
.....................
Using the Four-Parameter Display
.......................
Four-Parameter Display and Calibration
...................
‘lb
View
AR
Four S-Parameters of a Two-Port Device
.............
lb Activate and Configure the Auxiliary Channels
.............
Quick Four-Parameter Display
.......................
conttmts-1
l-l
l-2
l-4
l-7
l-11
1-13
1-13
1-13
1-13
1-13
1-13
1-13
1-13
1-13
1-14
1-14
1-15
2-l
2-2
2-3
2-3
2-3
2-3
2-3
2-3
2-4
2-4
2-4
2-5
2-5
2-6
2-6
2-7
2-7
2-8
2-8
2-8
2-9
2-10
2-10
2-10
2-12
2-13