HP (Hewlett-Packard) HP 8753E Network Cables User Manual


 
located under the
1Menu)
key, is the standard sweep mode of the
analyzer, in which the sweep is triggered automatically and
continuously and the trace is updated with each sweep.
brings up the conversion menu which converts the measured
data to impedance (Z) or admittance
(Y).
When a conversion
parameter has been defined, it is shown in brackets under the
softkey label. If no conversion has been defined, the softkey
. . . . . . . . . . . . . .
,.
_
,.
_
. . . . . . . .
,.;...
.,.,
;.,
.,...,.,,
.
.._
label
reads
~~~~~~~~~~~~~
-
:.:...;.::.::
. . . . . . . . . . . . . . . .
. . .
...................
..~...............................................
;;;..;;,
provides access to the menus used for controlling external
plotters and printers and
dehning
the plot parameters.
turns error correction on or off. The analyzer uses the most
recent calibration data for the displayed parameter. If the
stimulus state has been changed since calibration, the original
state is recalled, and the message “SOURCE PARAMETERS
CHANGED” is displayed.
switches the counter to count the analog bus.
switches the counter to count the
Al4
fractional-N VCO
frequency after it has been divided down to 100
kHz
for
phase-locking the VCO.
switches the counter to count the
Al4
fractional-N VCO
frequency at the node shown on the overall block diagram.
switches the internal counter off and removes the counter
display from the LCD.
toggles the channel coupling of stimulus values. With
.,.,.,.;
_
;,.,
_
_
/
. .
~~“.‘,.,.,.,.,.,...,.,.,.
;,._;
.
. . . . .
. .
.._....
__
_
. .
.
~~~~~;~~~~~~~~~~
(the preset condition), both channels have
i
-
.._....................-.......--
-
_.................
the same
stimuhis
values (the inactive channel takes on the
stimulus values of the active channel).
is used to set the frequency for power sweep and CW time
sweep modes If the instrument is not in either of these two
modes, it is automatically switched into CW time mode.
turns on a sweep mode similar to an oscilloscope. The analyzer
is set to a single frequency, and the data is displayed versus
me.
me
frequency
of
the
CW
we
sweep
&
set
with
~~~~~~
_
ii
_
_
_
i
_
_
_
_
_
in the stimulus menu.
this math function ratios channels 1 and 2, and puts the results
in the channel 2 data array.
Both
channels must be on and
have the same number of points Refer to Chapter 2, “Making
Measurements” for information on how to use this function to
make gain compression measurements.
displays both the current data and memory traces.
specifies whether or not to store the error-corrected data on
disk with the instrument state.
g-10
Key Definitions