CALCulate Subsystem
2–78
TVS600 & TVS600A Command Reference
CALCulate:WMParameter:LREFerence
CALCulate:WMParameter:RMEThod
CALCulate:WMParameter:MREFerence
CALCulate:WMParameter:MREFerence?
Sets or queries the middle reference (mesial) level in vertical units for time and
amplitude measurements. The MREFerence setting is effective only when
CALC:WMP:RMEThod is set to ABSolute.
CALCulate<n>:WMParameter:MREFerence[:ABSolute] <mrefā>
CALCulate<n>:WMParameter:MREFerence[:ABSolute]?
<n>
1
Query response
1
2
3
4
Not applicable
1
The calculate block number <n> selects one of four calculate blocks. If you omit <n>,
the default is calculate block 1.
<mref> (Set absolute value of MREF) Query response
<NRf> <NR3>
0.0E+0
Execution Error –222, “Data out of range”
Attempted to set the middle reference to an illegal value.
None
Command: CALC1:WMP:MREF 1
Query: CALC1:WMP:MREF?
Response: 1.0E+0
Related Commands
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples