STATus Subsystem
2–156
TVS600 & TVS600A Command Reference
STATus:OPERation:NTRansition
STATus:OPERation:NTRansition?
Sets or queries the contents of the Operation Negative Transition Register
(ONTR). When you set an event bit true (1) in the ONTR, the ONTR reports an
event in the Operation Status Register when the Operation Status Condition
Register event line changes from true to false (1 to 0)
. The query returns the
current setting as a decimal number whose bits correspond to the Operation
Status Register bits. Refer to Table 2–2 on page 2–152 for a definition of the
events associated with the Operation Status Register bits. The command
STATus:OPERation:PTRansition provides similar control for positive event
transitions. For an overview of the status and event reporting system, refer to the
TVS600 & TVS600A Series Waveform Analyzers User Manual.
STATus:PRESet sets all register bits to zero (0) which disables reporting
negative event transitions. Setting unused enable bits does not generate an error,
they are ignored.
STATus:OPERation:NTRansition <mask>
STATus:OPERation:NTRansition?
<mask> Query response
<NRf> | <Non-decimal numeric>
0 ≤ N ≤ #HFFFF
<NR1>
Not applicable
Execution Error –222, “Data out of range”
Attempted to set the transition register to an illegal value.
None
Command: STAT:OPER:NTR #H0010
This command, (decimal 16), sets the Operation Negative Transition
Register to set the Acquiring/Measuring event bit when the current
measurement or acquisition completes.
Query: STAT:OPER:NTR?
Response: 16
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples