STATus Subsystem
TVS600 & TVS600A Command Reference
2–155
STATus:OPERation:ENABle
STATus:OPERation:ENABle?
Sets or queries the contents of the Operation Status Enable Register (OSER).
The OSER allows you to individually disable any of the Operation events from
setting bit 7 in the Status Byte Register.
The query returns the current setting as a
decimal number whose bits correspond to the Operation Status Register bits.
Refer to Table 2–2 on page 2–152 for a definition of the events associated with
the Operation Status Register bits. Setting unused enable bits does not generate
an error, they are ignored. For an overview of the status and event reporting
system, refer to the TVS600 & TVS600A Series Waveform Analyzers User
Manual.
STATus:PRESet sets all register bits to zero (0) which disables all Operation
events.
STATus:OPERation:ENABle <mask>
STATus:OPERation:ENABle?
<mask> Query response
<NRf> | <Non-decimal numeric>
0 ≤ N ≤ #HFFFF
<NR1>
Not applicable
Execution Error –222, “Data out of range”
Attempted to set the enable register to an illegal value.
None
Command: STAT:OPER:ENAB #H0010
This command, (decimal 16), enables only the Acquiring/Measuring
event.
Query: STAT:OPER:ENAB?
Response: 16
STATus:OPERation?
STATus:OPERation:CONDition?
STATus:PRESet
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands