Tektronix TVS600 & TVS600A Series Computer Accessories User Manual


 
SWEep Subsystem
TVS600 & TVS600A Command Reference
2–177
<record_length> (Number of data points) Query response
<NRf>
256
512
1024
2048
4096
8192
15000
30000 (ERT mode only)
MINimum
MAXimum RT mode
MAXimum ERT mode
<NR1>
256
512
1024
2048
4096
8192
15000
30000
256
15000
30000
1024
Execution Error –222, “Data out of range”
Attempted to set record length:
to an illegal value or
to a value > 15,000 while in real time acquisition or
to a value > 30,000 while in extended real time acquisition.
Changing SWEep:POINts changes SWEep:TIME if SWEep:TINTerval
remains constant. The relationship is
SWEep:TINTerval = SWEep:TIME / SWEep:POINts.
Command: SWE:POIN 1000
Query: SWE:POIN?
Response: 1024
SWEep:TINTerval
SWEep:TIME
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands