Tektronix TVS600 & TVS600A Series Computer Accessories User Manual


 
TRIGger:LOGic Subsystem
TVS600 & TVS600A Command Reference
2–265
TRIGger:LOGic:PATTern:WIDTh
TRIGger:LOGic:PATTern:WIDTh?
TVS600A Models Only
Sets or queries the width of the pattern when time qualification is enabled.
:A is a predefined alias for :SEQuence[1].
This command only has effect when TRIGger:TYPE is LOGic, TRIGger:LOG-
ic:CLASs is PATTern, and TRIGger:LOGic:PATTern:QUALify is LT or GT.
TRIGger[:A]:LOGic:PATTern:WIDTh <time>
TRIGger[:A]:LOGic:PATTern:WIDTh?
<time> Query response
<NRf>
MINimum
MAXimum
<NR3>
2.0E–9
1.0E+0
S (default), MS, US, NS, or PS
5.0E–9
Execution Error –222, “Data out of range”
Attempted to set WIDTh to an illegal value.
None
Command: TRIG:LOG:PATT:WIDT 0.001
Query: TRIG:LOG:PATT:WIDT?
Response: 1.0E-3
TRIGger:TYPE
TRIGger:LOGic:CLASs
TRIGger:LOGic:PATTern:QUALify
Syntax
Parameters
Suffix Units and
Multipliers
Reset Value
Errors and Events
Dependencies
Examples
Related Commands