Tektronix TVS600 & TVS600A Series Computer Accessories User Manual


 
TRIGger:PULSe Subsystem
TVS600 & TVS600A Command Reference
2–279
TRIGger:PULSe:WIDTh:LLIMit
TRIGger:PULSe:WIDTh:LLIMit?
Sets or queries the lower or minimum valid pulse width to qualify for pulse
triggering. The pulse on the trigger source must take longer than the :WIDTh
value to cross the TRIGger:PULSe:THReshold level. To activate this command,
set TRIGger:TYPE to PULSe and TRIGger:PULSe:CLASs to WIDTh.
TRIGger[:A]:PULSe:WIDTh:LLIMit <llimit>
TRIGger[:A]:PULSe:WIDTh:LLIMit?
<llimit>
1
Query response
<NRf>
MIN
MAX
<NR3>
2.0E–9
1.0E+0
1
The default for the parameter <llimit> is seconds (S). You can also use the
multipliers MS for milliseconds, US for microseconds, NS for nanoseconds, and PS
for picoseconds.
2.0E–9
Execution Error –222, “Data out of range”
Attempted to set lower limit to an illegal value.
None
Command: TRIG:PULS:WIDT:LLIM 0.1
Query: TRIG:PULS:WIDT:LLIM?
Response: 100.0E-3
TRIGger:TYPE
TRIGger:PULSe:CLASs
TRIGger:PULSe:WIDTh:HLIMit
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands