Tektronix TVS600 & TVS600A Series Computer Accessories User Manual


 
TRIGger:SHOLdtime Subsystem
TVS600 & TVS600A Command Reference
2–291
TRIGger:SHOLdtime:STIMe
TRIGger:SHOLdtime:STIMe?
TVS600A Models Only
Sets or queries the setup time that violations will be checked against.
:A is a predefined alias for :SEQuence[1].
Positive values for setup time occur before the clock edge; negative values
occure after the clock edge.
Positive values for both setup and hold times create a time zone that spans the
clocking edge.
Negative setup and positive hold times create a time zone that follows the
clocking edge.
Positive setup and negative hold times create a time violation zone that precedes
the clocking edge.
The sum of the setup and hold times can not be less than 2ns. Setting one time
will change the other time if this restriction is violated.
This command only has effect when TRIGger:TYPE is SHOLdtime.
TRIGger[:A]:SHOLdtime:STIMe <setuptime>
TRIGger[:A]:SHOLdtime:STIMe?
<setup time> Query response
<NRf>
MINimum
MAXimum
<NR3>
–100.0E–9
100.0E–9
S (default), MS, US, or PS
4.0E–9
Execution Error –222, “Data out of range”
Attempted to set setup time to an illegal value.
None
Syntax
Parameters
Suffix Units and
Multipliers
Reset Value
Errors and Events
Dependencies