Tektronix TVS600 & TVS600A Series Computer Accessories User Manual


 
CALCulate Subsystem
TVS600 & TVS600A Command Reference
2–37
CALCulate:FILTer:FREQuency:SPAN
CALCulate:FILTer:FREQuency:SPAN?
Sets or queries the frequency range to be used by the bandpass and notch filters.
After you define the range with :SPAN, you position the range within the
available spectrum using the command :FREQuency:CENTer. For example, if
you set :SPAN to 2 MHz and :CENTer to 10 MHz, then the :NOTCh filter will
have a range of 9 MHz to 11 MHz.
The frequency span is ignored when you select the high-pass (:HPASs) or
low-pass (:LPASs) filter.
CALCulate<n>:FILTer[:GATE]:FREQuency:SPAN <span>
CALCulate<n>:FILTer[:GATE]:FREQuency:SPAN?
<n>
1
Query response
1
2
3
4
Not applicable
1
The calculate block number <n> selects one of four calculate blocks. If you omit <n>,
the default is calculate block 1.
<span> (Frequency range)
1
Query response
<NRf> <NR3>
1
The default multiplier for the parameter <span> is HZ for hertz. You can also use the
multipliers KHZ for kilohertz, MHZ for megahertz, and GHZ for gigahertz.
100.0E+6
Execution Error –222, “Data out of range”
Attempted to set span to an illegal value.
You can set the frequency range for the frequency filters :NOTCh and :BPASs
with either the command pair :CENTer and :SPAN or the command pair :STARt
and :STOP. Because both command pairs control the same parameters, changing
either command pair will affect the other.
Command: CALC1:FILT:FREQ:SPAN 10E3
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples