Tektronix TVS600 & TVS600A Series Computer Accessories User Manual


 
TRIGger:B Subsystem
2–250
TVS600 & TVS600A Command Reference
TRIGger:B:ECOunt
TRIGger:B:ECOunt?
Sets or queries the number of B trigger events to count before starting acquisi-
tion. The number of B trigger events is ignored when you set TRIG-
ger:B:SOURce to IMMediate.
TRIGger:B:ECOunt <delay_events>
TRIGger:B:ECOunt?
<delay_events> Query response
<NRf>
1 N 10,000,000
MINimum
MAXimum
<NR1>
1
10000000
1
Execution Error –222, “Data out of range”
Attempted to set B trigger events to an illegal value.
Setting TRIGger:B:ECOunt to a value greater than 1 when TRIGger:B:SOURce
is set to INTernal or EXTernal sets TRIGger[:A]:DELay to 0.
Command: TRIG:B:ECO 100
Query: TRIG:B:ECO?
Response: 100
TRIGger[:A]:DELay
TRIGger:B:DELay
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands