Tektronix TVS600 & TVS600A Series Computer Accessories User Manual


 
TRIGger:B Subsystem
TVS600 & TVS600A Command Reference
2–249
TRIGger:B:DELay
TRIGger:B:DELay?
Sets or queries the trigger delay for the Trigger B circuit. Trigger delay sets the
time after the Trigger B event to start acquisition. TRIGger:B:DELay is always
positive which delays the start of acquisition a specified time after the trigger
event. The minimum real delay is 16 ns. Setting TRIGger:DELay to 0 indicates
no delay and bypasses the delay counter. Use SWEep:OFFSet:TIME to acquire
pretrigger data.
For further information, refer to the TVS600 & TVS600A Series Waveform
Analyzers User Manual.
TRIGger:B:DELay <delay_time>
TRIGger:B:DELay?
<delay_time>
1
Query response
<NRf>
16 ns N 250 s (in 4 ns steps )
MINimum
MAXimum
<NR3>
0.0E+0
250.0E+0
1
The default for the parameter <delay_time> is seconds (S). You can also use the
multipliers MS for milliseconds, US for microseconds, and NS for nanoseconds.
0.0E+0
Execution Error –222, “Data out of range”
Attempted to set B trigger delay to an illegal value.
Setting TRIGger:B:DELay to a value greater than 0 will cause TRIG-
ger[:A]:DELay to be set to 0. Only one of the delays may operate at a time.
Command: TRIG:B:DEL 10E-6
Query: TRIG:B:DEL?
Response: 10.0E-6
SWEep:OFFSet:TIME
TRIGger[:A]:DELay
TRIGger:B:ECOunt
Syntax
Parameters
Reset Value
Errors and Events
Dependencies
Examples
Related Commands