Polycom 7.5 Webcam User Manual


 
Chapter 5 - Monitoring Conferences
5-62
Sync Counters
Status (cont.)
Protocol Sync Loss - Indicates whether the system was able
to synchronize the bits order according to the selected video
protocol (H.261 or H.263). This option is checked when there
is a problem in the second stage of the synchronization. The
counter indicates the number of times the system tried to
synchronize.
Video Intra Sync - Intra is a special video frame that is used
for synchronization. Indicates whether the synchronization on
a video H.261 or H.263 Intra frame was successful.
Video Resolution - The video resolution of the participant.
l-sync video
loss (0)
A checked check box indicates that there is a video
synchronization problem in the participant's endpoint. The
counter indicates the number of times the MCU had to re-
synchronize.
Note: This parameter is only relevant in Continuous Presence
conferences.
r-sync video
loss (0)
A checked check box indicates that there is a video
synchronization problem in the MCU. The counter indicates
the number of times the endpoint had to re-synchronize.
Note: This parameter is only relevant in Continuous Presence
conferences.
FECC Token When checked, indicates that the participant is holding the
Data Token.
Content Token When checked, indicates that the participant is holding the
Content Token.
Table 5-15: IP Participant Connection Info1 - Channel Status (Continued)
Field/Option Description