802.3ah | 101
Frame Errors per Second
Frame Errors per Frame Period
Error Seconds per Time Period
Task Command Syntax Command Mode
Specify the high threshold value for
frame errors, or disable the high
threshold.
ethernet oam link-monitor frame threshold high
{
frames | none}
Range: 1-65535
Default: None
INTERFACE
Specify the low threshold for frame
errors.
ethernet oam link-monitor frame threshold low frames
Range: 0-65535
Default: 1
INTERFACE
Specify the time period for frame
errors per second condition.
ethernet oam link-monitor frame window milliseconds
Range: 10-600 milliseconds
Default: 100 milliseconds
INTERFACE
Task Command Syntax Command Mode
Specify the high threshold value for
frame errors per frame period, or
disable the high threshold.
ethernet oam link-monitor frame-period threshold
high {frames | none}
Range: 1-65535
Default: None
INTERFACE
Specify the low threshold for frame
errors per frame period.
ethernet oam link-monitor frame-period threshold low
frames
Range: 0-65535
Default: 1
INTERFACE
Specify the frame period for frame
errors per frame period condition.
ethernet oam link-monitor frame-period window
milliseconds
Range: 1-65535 (times 10,000 frames)
Default: 1000 (10 million frames)
INTERFACE
Task Command Syntax Command Mode
Specify the high threshold value for
frame error seconds per time period, or
disable the high threshold.
ethernet oam link-monitor frame-seconds threshold
high {milliseconds | none}
Range: 1-900
Default: None
INTERFACE
Specify the low threshold for frame
error seconds per time period.
ethernet oam link-monitor frame-seconds threshold
low milliseconds
Range: 1-900
Default: 1
INTERFACE