1218 | E-Series TeraScale Debugging and Diagnostics
www.dell.com | support.dell.com
Flexible packet classifier hardware errors
FTOS displays Message 19 in case of a parity error on an FPC. Configure an action using the command
hardware monitor linecard asic fpc action-on-error. You may place the line card in a problem state, reset the
card, or shutdown all ports on the card.
Line card MAC hardware errors
FTOS displays Message 20 in case of a port hang error. Configure an action using the command hardware
monitor mac action-on-error port-shutdown
. You may only shutdown all ports on the card with this
command.
Core dumps
RPM core dumps
The RPM supports two types of core dumps for RPMs—application and kernel.
Message 17 Low Free Memory Error
%RPM0-P:CP %CHMGR-1-LF_MEM_ERR: Low free memory error detected on Ingress BTM port-pipe 0
Line card slot 9
%RPM0-P:CP %CHMGR-1-LF_MEM_ERR: Low free memory error detected on Egress BTM port-pipe 1 Line
card slot 9
Message 18 Start-of-Packet/End-of-Packet Memory Error
%RPM0-P:CP %CHMGR-1-SOP_EOP_ERR: SOP/EOP error detected on Ingress BTM port-pipe 1 Line card
slot 9
%RPM0-P:CP %CHMGR-1-SOP_EOP_ERR: SOP/EOP error detected on Unknown slot 9
Message 19 Parity Error
%RPM0-P:CP %CHMGR-2-CARD_PARITY_ERR: Linecard 9 pp 0 FPC SRAM Hard parity error: Address
0x85000 Index 0x80000 Check the Hardware Log
%E48TF:9 %POLLMGR-5-FPC_NOTIFY: Line card detected FPC 9 parity - Transient phantom
%E48TF:9 %POLLMGR-5-FPC_NOTIFY: Line card detected FPC 9 parity - Transient recoverable
Message 20 Port Hang Error
%E48TF:9 %IFAGT-5-PORT_HUNG: Port hang detected on slot 9 port 2
%E48TF:9 %IFAGT-5-PORT_HUNG: Port hang detected on slot 9 port 26