1012 | SONET/SDH
www.dell.com | support.dell.com
Use the alarm-report command to configure the SONET alarms that a POS or 10 GE WAN interface can
activate.Table 49-2 defines the alarms that you can enable.
To view active alarms and defects, use the
show controllers sonet command in EXEC Privilege mode.
When an E-Series POS or 10GE WAN interface detects a SONET alarm, a Syslog and SNMP trap message
are generated containing information about the alarm condition.
Task Command Syntax Command Mode
Specify which POS/SDH alarms to report
to the remote SNMP server.
alarm-report {lais | lrdi | pais | plop | prdi
|
sd-ber | sf-ber | slof | slos}
INTERFACE
Note: Historical data is not saved. The command input will show current information only.
Table 49-2. Alarm Definitions
Alarm Description
lais Line Alarm Indication Signal
lrdi Line Remote Defect Indication
pais Path Alarm Indication Signal
plop Path loss of Pointer
prdi Path Remote Defect Indication
sd-ber LBIP BER in excess of Signal Degradation threshold
sf-ber LBIP BER in excess of Signal Failure threshold
slof Section Loss of Frame
slos Section Loss of Signal