1170 | C-Series Debugging and Diagnostics
www.dell.com | support.dell.com
Figure 60-3. show sfm Command Example
Use the FTOS Syslogging feature to monitor the overall status of the switch fabric. Changes in switch
fabric status are reported via messages similar those in Message 2.
Runtime hardware status monitoring
The FTOS Poll Manager (POLLMGR) process reads the key status registers on hardware sub-components
to pro-actively identify and report a hardware fault. An example Syslog message is shown in Message 3.
The Poll Manager runs automatically in the background and cannot be disabled. The possible Poll
Manager Syslog messages are given in Table 60-2.
Message 2 Switch Fabric Status Change Syslog Message Example
00:00:13: %RPM1-P:CP %TSM-6-SFM_FULL_PARTIAL_STATE: SW_FAB_UP_1 SFM in the system
00:00:13: %RPM1-P:CP %TSM-6-SFM_SWITCHFAB_STATE: Switch Fabric: UP
Message 3 Poll Manager Syslog Message Example
%RPM1-P:CP %POLLMGR-2-BPL_IRC_ERR: Back Plane Link Error
Table 60-2. Poll Manager Syslog Message Description
Message Description
POLLMGR-2-ALT_RPM_STA
TE
Reports that either the standby RPM is not present or has been detected.
POLLMGR-2-USER_FLASH_
DETECT
Reports the status of the flash disks.
If reported during boot up, this message indicates either:
a External flash disk missing in slot0:
b Internal flash disk missing in flash:
If reported during runtime, this message indicates either:
a External flash disk removed from slot0:
b Internal flash disk removed from flash:
FTOS#show sfm
Switch Fabric State: up
-- SFM 0 --
Status : active
Module Type : SFM - Switch Fabric Module
Up Time : 1 day, 6 hr, 0 min
-- SFM 1 --
Status : not present