HP (Hewlett-Packard) B6960-90078 Computer Drive User Manual


 
Integrations with Other Applications
MC/ServiceGuard Integration
Chapter 13 633
/opt/omni/sbin/install/omniforsg.ksh -secondary
/omni_shared
5. Unmount the mount point directory (Data Protector shared
directory):
umount /omni_shared
6. Deactivate the volume group you imported:
vgchange -a n /dev/vg_ob2cm
Configuring the Cell Manager Package
NOTE The following section provides step-by-step examples to configure the
Data Protector package. Directory and file names, numbers, and other
variables will differ from the following examples according to your
environment. The cluster configuration file name cluster.conf and the
Data Protector package name ob2cl is used also as an example. You
should follow the names given to you by your network or domain
administrator.
Note that the Data Protector daemons are not running anymore on
either cluster node.
Prerequisites The Data Protector Cell Manager should be installed and configured
on both cluster nodes as explained in the previous section.
Before configuring the Data Protector cluster package, you should
have a cluster configuration file created and edited.
Configuring Data
Protector Package
On the Primary Cell Manager node proceed as follows:
1. Check the cluster configuration file for errors:
cmcheckconf -C /etc/cmcluster/cluster.conf
If there are errors, fix them.
If there are no errors, enable the configuration:
cmapplyconf -C /etc/cmcluster/cluster.conf
2. Start the cluster:
cmruncl