Further Information
Disaster Recovery: Move Kill Links on HP-UX 11.x
Appendix A A-25
Disaster Recovery:
Move Kill Links on HP-UX 11.x
Proceed as shown below on the system which you want to back up to
move some links:
# The system will go from "run-level" 4 to "run-level 1"
# retaining the inetd, networking, swagentd services up.
The state is called "minimum activity" for backup
purposes (need networking).
# IMPORTANT: ensure the links are present in /sbin/rc1.d
before
# moving and they do have this exact name. You have to
rename them for the rc0.d directory. Put them BELOW the
lowest (original "/sbin/rc0.d/Kxx") "K...-link" in rc0.d
# Move K430dce K500inetd K660net K900swagentd into
../rc0.d BELOW the lowest kill link!!!
echo "may need to be modified for this system"
exit 1
#
cd /sbin/rc1.d
mv K430dce ../rc0.d/K109dce
mv K500inetd ../rc0.d/K110inetd
mv K660net ../rc0.d/K116net
mv K900swagentd ../rc0.d/K120swagentd