3-28 C122-E003-02EN
MMB
CHAPTER 3 Web-UI Operations
(1) Menu operation
[System] → [Power Supply]
(2) GUI operation
None
Power System
Redundancy
Redundancy status of power supply units:
• Redundant: PSU redundancy is maintained.
• [Non-redundant: FSufficient Resources]: PSU redundancy is
lost, but there are enough PSUs to continue system operation.
• [Non-redundant: Insufficient Resources]: PSU redundancy is
lost, and there are not enough PSUs to continue system
operation.
UPC#x UPS status detected by the UPC interface:
• AC Lost: Power is off.
• Battery Lost: The battery has been depleted.
• Failed: The system has failed.
• -: Normal status or the UPS is not connected.
PSU
PSU PSU number
Status PSU status:
• OK: Operating normally
• Not present: Not installed
• Failed: Failure
• Predictive Fail: Expecting a failure.
• A/C Lost: Power failure
Power Status Indication of whether PSU power is On or Off
Part Number PSU part number
Serial Number PSU serial number
Item Description