C122-E003-02EN 3-165
MMB
3.6 Maintenance Menu
3.6.1.5 BMC Firmware Update window
BMC firmware can be updated in the [BMC Firmware Update] window.
Note: When the BMC is updated, the BMC reboots itself, causing a temporary
interruption in service. To prevent possible problems, Fujitsu recommends
that partitions linked to the BMC to be updated be shut down before the
update.
Figure 3.80 [BMC Firmware Update] window
Uninstalled devices and partitions that have not been configured are grayed out and
cannot be selected.
Table 3.130 Displayed and setting items in the [BMC Firmware Update]
window
Item Description
Select BMM(s) to
update
Select the BMM units that store BMC firmware by clicking a radio
button as follows:
• All: Used to select all BMMs installed in the system.
• Specified unit(s): Used to select either BMM board.
• Specified partition(s): Used to select a partition.
Only the check boxes of units next to a clicked radio button can be
checked. Other check boxes are grayed out, and input for them is
not possible.
Select BMC firmware
file
Specify an update file containing BMC firmware.