8-98 C122-E003-02EN
GSWB
CHAPTER 8 CLI Operations
• % Not implement daughter card.
Cause: TenGigabitEthernet was specified for the unit where 10GigabitEthernet was
not implemented.
Action: Check the device configuration.
• Input parameter duplicate error.
Cause: Duplicated registration was attempted.
Action: Check the entries already registered.
• Entry isn't existed.
Cause: Deletion of an entry was attempted but the entry did not exist.
Action: Check the entries already registered.
• source/destination can't be registered at same port.
Cause: Registering a port with both [source] and [destination] was attempted.
Action: Check the entries already registered.
• Input parameter error.
Cause: An invalid parameter was specified.
Action: Specify the correct parameter.
8.2.13.2 monitor session destination
This command specifies the mirror port.
Only one port can be set as the mirror port. The port specified by the monitor session
destination command cannot be used as a normal port. No setting can be made for a
port-channel. Any interface registered by the monitor session source command
cannot be registered.
By default, no entry is registered.
(1) Synopsis
• Specifies the mirror port
• Resets the mirror port setting to the default value
monitor session destination interface <interface-id>
no monitor session destination