C122-E003-02EN 8-177
GSWB
8.3 Operation Commands
z Running Config: Configuration definition file information at startup and creation
date.
z Running Offline: Offline firmware information at startup and firmware version
number and creation date
z online Information: Status of online0/1 and config0/1. "*" indicates the beginning
of the current EEPROM information.
- online0/1: Firmware version number and creation date.
If a firmware error is detected, "*** Invalid online ***" is displayed.
- config0/1: Firmware version number and creation date.
Comments specified by the save config command are displayed between [ and ],
under the date.
If no file is found, "*** No File ***" is displayed.
If the file header is missing, "*** Error File ***" is displayed.
z Globalmac: Global MAC address (XX:XX:XX:XX:XX:XX)
z offline Information:
- Version number and creation date of the offline0/1 firmware. "*" indicates the
firmware that is started the next time.
If a firmware error is detected, "*** Invalid offline ***" is displayed.
(6) Error Messages
• % Incomplete command.
Cause: Incomplete command input
Action: Enter the command string correctly.
• % Invalid input detected at '^' marker.
Cause: Invalid character detected at '^' marker in the entered command string
Action: Enter the command string correctly.
• System error.
Cause: An internal error occurred.
Action: Check the system status, and reenter the command. If the error occurs again,
collect unit information, configuration definition information, and the
information in different types of logs, and restart the unit. Alternatively,
contact a certified service engineer.
• Command is already running.
Cause: The following command is running.
install