C122-E003-02EN 8-101
GSWB
8.2 Configuration Definition Commands
(3) Command mode
Global
(4) See also
None
(5) Examples
• Switches to interface configuration mode of GigabitEthernet 0/1
(6) Error Messages
• % Incomplete command.
Cause: Incomplete command input
Action: Enter the command string correctly.
• % Invalid input detected at '^' marker.
Cause: Invalid character detected at '^' marker in the entered command string
Action: Enter the command string correctly.
• Internal communication error.
Cause: An internal error occurred.
Action: Check the system status, and reenter the command. If the error occurs again,
collect unit information, configuration definition information, and the
information in different types of logs, and restart the unit. Alternatively,
contact a certified service engineer.
Switch(config)# interface GigabitEthernet 0/1
Switch(config-if)#