8.2 Configuration Definition Commands
(4) See also
monitor session destination
(5) Examples
• Sets GigabitEthernet 0/1 as a monitored port
• Deletes GigabitEthernet 0/1 from the monitored ports
• Uses the show command to check settings
(6) Error Messages
• % Incomplete command.
Cause: Incomplete command input
Action: Enter the command string correctly.
• % Invalid input detected at '^' marker.
Cause: Invalid character detected at '^' marker in the entered command string
Action: Enter the command string correctly.
• Internal communication error.
Cause: An internal error occurred.
Action: Check the system status, and reenter the command. If the error occurs again,
collect unit information, configuration definition information, and the
information in different types of logs, and restart the unit. Alternatively,
contact a certified service engineer.
Switch(config)# monitor session source interface GigabitEthernet 0/1 both
Switch(config)#
Switch(config)# no monitor session source interface GigabitEthernet 0/1
Switch(config)#
Switch(config)# show monitor session source
Switch(config)#
Switch(config)# monitor session source interface GigabitEthernet 0/1 both
Switch(config)# monitor session source interface GigabitEthernet 0/2 rx
Switch(config)# monitor session source interface GigabitEthernet 0/3 tx
Switch(config)# show monitor session source
monitor session source interface GigabitEthernet 0/1 both
monitor session source interface GigabitEthernet 0/2 rx
monitor session source interface GigabitEthernet 0/3 tx
Switch(config)#