C122-E003-02EN 3-69
MMB
3.2 System Menu
Table 3.46 Button in GSWB#x window
(1) Menu operation
[System] → [GSWB] → [GSWB#x]
(2) GUI operation
1 Click the [Status Clear] button.
A confirmation dialog box opens for confirmation to clear the error status of
the GSWB.
2 Click the [OK] button in the dialog box to clear the error status of the GSWB.
The error status is cleared, and use of the GSWB is attempted at the next
reboot.
To not clear the error status of the GSWB, click the [Cancel] button in the
dialog box.
Voltage Current voltage reading
Threshold Warning
(Low/High)
Lower and upper limits of the warning-level voltage. If no limit is
set, "-" is displayed.
Critical
(Low/High)
Lower and upper limits of the critical-level voltage. If no limit is
set, "-" is displayed.
Button Description
Status Clear Clears the error status of the GSWB and attempts to use the GSWB
at the next reboot.
Item Description