Fujitsu F2MCTM-16LX Computer Hardware User Manual


 
116
CHAPTER 6 CLOCK SUPERVISOR
The sub-clock supervisor is operated by setting SSVE(CSVCR:bit2) to 1. Please note the programming
of software to do after 10 µs or more has passed since the CR oscillation circuit was set enable.
Sub-clock Mode
The main clock supervisor automatically becomes disable at the sub-clock mode. The content of enable bit
MSVE never changes. If the main clock was lost after oscillation stability waiting time of 2
11
/HCLK
(about 0.51 ms: at external 4 MHz) or before the oscillation stability waiting time ends, the main clock
supervisor is valid after it passes of 2
12
cycles of the CR oscillation clock (about 41 ms: at CR oscillation
100 kHz) at transition from main clock mode to sub clock mode.
Sub-clock Mode Transition Operating When Sub-clock Has Already Stopped
The behavior that shifts to the sub-clock mode depends on the state of the SRST bit when the stop of the
sub-clock is detected by the sub-clock supervisor while the device is operating in the main clock mode.
When SRST is set to 0 (initial state), the reset is not generated at transition to the sub-clock mode. In
this case, the CR oscillation clock is used as a sub-clock at transition to the sub-clock mode.
When SRST is set to 1, the reset is generated at transition to the sub-clock mode.
Stop Mode
CR oscillation circuit, the main clock, and the sub-clock supervisor automatically become disable at
transition to the stop mode, when all of these functions are enable. Each enable bit of the clock supervisor
control register is not changed. Therefore, after it is released from the stop mode, each enable/disable state
of CR oscillation circuit and clock supervisor keep the state before they changes to the stop mode.
The CR oscillation circuit immediately becomes enable after released from the stop mode.
If the main clock was lost after oscillation stability waiting time of 2
11
/HCLK (about 0.51 ms: at
external 4 MHz) or before the oscillation stability waiting time ends, the main clock supervisor is
enabled after it passes of 2
12
cycles of the CR oscillation clock (about 41 ms: at CR oscillation 100
kHz).
After it passes of 2
18
cycles of the CR oscillation clock (For about 2.6 s:CR oscillation 100 kHz), the
sub-clock supervisor is valid.
Sub-clock Mode with External Single Clock Product
In the sub-clock mode with external single clock product ("S" suffix product), the CR oscillation clock can
be used as a sub-clock.
To use this function, SCKS (bit7 of CSVCR) is set to 1 and SRST is set to 0 (initial value). This function
can not be used with the external dual clock products (no "S" suffix product).