9-72 PPC405 Core User’s Manual
lbzu
Load Byte and Zero with Update
lbzu
Load Byte and Zero with Update
EA ← (RA|0) + EXTS(D)
(RA)
← EA
(RT)
←
24
0 || MS(EA,1)
An effective address (EA) is formed by adding a displacement to a base address. The displacement is
obtained by sign-extending the 16-bit D field to 32 bits. The base address is 0 if the RA field is 0 and
is the contents of register RA otherwise. The EA is placed into register RA.
The byte at the EA is extended to 32 bits by concatenating 24 0-bits to its left. The result is placed into
register RT.
Registers Altered
•RA
•RT
Invalid Instruction Forms
• RA=RT
• RA=0
Architecture Note
This instruction is part of the PowerPC User Instruction Set Architecture.
lbzu RT, D(RA)
35 RT RA D
0 6 11 16 31