3Com 5104M-FIB Switch User Manual


 
SET BPORT_MAU REMOTE_DIAGNOSTICS
2-95
SET BPORT_MAU
REMOTE_DIAGNOSTICS
Use the SET BPORT_MAU REMOTE_DIAGNOSTICS command to enable or
disable remote diagnostics sensing on a 10BASE-FB/FL SwitchModule port MAUs
operating in 10BASE-FL mode. Enable remote diagnostics when a 10BASE-FL
SwitchModule port MAU is connected to a pair of 10BASE-FL ports configured
for redundancy.
Remote diagnostics forces a SwitchModule 10BASE-FL port to stop transmitting
if it stops receiving signalling from a remote primary port. When transmission
ceases, the remote primary port detects that the link is down and switches to its
redundant (backup) port, reenabling the fiber link.
By default, remote diagnostics is disabled.
Format
Example
The following command enables remote diagnostics on 10BASE-FL
SwitchModule port 4 in slot 5:
CB5000> set bport_mau 5.4.1 remote_diagnostics enable
Related Command
SHOW BPORT_MAU VERBOSE
slot.port.mau Identifies the port for this operation.
slot (1 through 17) is the slot number and port (1 through 20) is the
port number. Use 1 as the mau variable. For example, to identify port
4 on the module in slot 6, enter
6.4.1
slot.
all
Specifies that all ports in the slot are affected by this operation.
disable
Disables remote diagnostics.
enable
Enables remote diagnostics.
slot.
all
set bport_mau remote_diagnostics
disable
enable
slot.port.mau