3Com 5104M-FIB Switch User Manual


 
2-190
SET PORT NETWORK
SET PORT NETWORK
Use the SET PORT NETWORK command to assign a port to a specific network.
This command applies to 3Com modules that support port-switching.
You may either:
Assign each port to one of the selected networks that are available for the
module type (Token Ring, Ethernet, or FDDI)
Isolate the port
Ports assigned to:
The same network form a segment (that is, they are on the same network).
Different networks are on different segments and cannot communicate
unless you bridge the networks. Each isolated port joins traffic from all other
ports on the same isolated (module-level) network.
All Ethernet modules are factory-set through the DIP switches or non-volatile
RAM so that the ports are assigned to channel 1 (Ethernet network 1). Change
the DIP switch setting only if your hub is without a management module.
This command applies only to 3Com modules that have individual ports that are
network-selectable. For modules that are network-selectable per module, refer
to the SET MODULE NETWORK command.
Format
Example 1
The following command sets port 2 on the module in slot 5 to network
Ethernet 1:
CB5000> set port 5.2 network ethernet_1
Port 05.02 network id set to ETHERNET_1
Example 2
The following command sets port 1 on the ONline Ethernet Bridge Module in
slot 7 to the AUI port on the front panel:
ONline>
set port 7.1 network front_panel
Port 07.01 network id set to FRONT_PANEL
slot.port Selects the port to assign to a network.
slot (1 through 17) is the number location of a module in the hub
and port (1 through 40) is the port number on the specified module.
For example, to specify port 4 on the with ID 6, enter
6.4
slot.
all
Selects a module to assign to a network. For example, to specify all
ports on the module with slot ID 6, enter
6.all
network Specifies the network to which you are assigning the port. For
example, ethernet_2.
slot.
all
set port network
slot.port network