3Com 5104M-FIB Switch User Manual


 
SET ATM SIGNAL
2-65
SET ATM SIGNAL
Use the SET ATM SIGNAL command to specify parameters for the signalling
Virtual Channel Connection (VCC). The parameters you set take effect at the
next module reset.
Format
Example
The following command sets the maximum ATM signal burst size in cells to 9:
CB5000> set atm 4 signal max_burst_size 9
Slot 04 parameter set.
Related Command
SET ATM ILMI
slot Identifies the slot for this operation.
slot (1 through 17) is the slot number.
max_burst_size
Specifies the maximum burst size (in cells).
option Choose from a range of 1 through 100. The default value is 7.
peak_cell_rate
Specifies the peak cell rate as a percentage of line rate.
option Choose from a range of 1 through 100. The default value is 5.
sust_cell_rate
Specifies the sustained cell rate as a percentage of line rate.
option Choose from a range of 1 through 100. The default value is 1.
set atm
signal
slot
max_burst_size
peak_cell_rate
sust_cell_rate
option
option
option