SET PORT COLLISION
2-177
SET PORT COLLISION
Use the SET PORT COLLISION command to establish if normal or alternate
collision mode is used for that port on the ONline Ethernet Transceiver Module.
Refer to the
ONline Ethernet Transceiver Module Installation Guide
for more
information on collision mode and the Ethernet Transceiver module.
Format
Example
The following command sets port 3 in slot 6 to normal collision mode:
CB5000> set port 6.3 collision normal
Collision set to NORMAL.
Related Command
SHOW PORT
slot.port Identifies the port for this operation.
slot (1 through 17) is the slot number location of a module in the hub
and port (1 through 3) is the port number on the specified module.
For example, to identify port 3 on the module in slot 6, enter
6.3
slot.
all
Specifies that all ports on the module are affected by this operation.
alternate
Specifies alternate mode. Used primarily with non-IEEE 802.3 devices.
normal
Specifies normal mode. Default setting, used primarily with IEEE 802.3
devices and repeaters.
slot.
all
set port collision
alternate
normal