3Com 5104M-FIB Switch User Manual


 
SHOW TR_SURROGATE REM_THRESHOLD_ EXCD
2-409
SHOW
TR_SURROGATE
REM_THRESHOLD_
EXCD
Use the SHOW TR_SURROGATE REM_THRESHOLD_EXCD command to show
information about the most-recently detected threshold exceeded condition. The
REM Non-Isolating Threshold Exceeded Table displays information used to build a
trap that describes the soft error counter that has been exceeded.
Format
Example
The following command displays information about the most-recently detected
threshold exceeded condition for the TR-NMC in slot 11.2:
CB5000> show tr_surrogate 11.2 rem_threshold_excd
Ring Error Monitor Non-Isolating Threshold Exceeded Data for Network
TOKEN_RING_1
--------------------------------------------------------------------
Lost Frame Errors: 0
Receiver Congestion Errors: 0
Frame Copied Errors: 0
Frequency Errors: 0
Token Errors: 0
Table Full Conditions: 0
Minimum Decrement Exceeded Errors: 0
Receiver Congestion Table-Full Conditions: 0
Related Command
SET TR_SURROGATE
show tr_surrogate
slot.
2
rem_threshold_excd
slot.
2
The slot ID for the module that you selected for the operation. The slot
number can be from 1 through 17. The subslot is always 2.